Now the confusion is that the label figure do not tally with the one calculated from your explanation if i really grasped it.
Finding max current of solar panel.
Electrical power in kwp of one solar panel divided by the area of one panel.
If you plot voltage vs current you ll see that as the load current is increased the output voltage on the panel drops.
As you can see for low currents the voltage varies slightly and for low voltages the current is almost constant.
Example of i v curve and ratings of a 12 v pv solar panel.
This maximum power point in the example curve given above is where vmp is 17 volts and the current imp is 2 5 amps.
Radiation 1000 w m2 cell temperature 25 celcius degree wind speed 1 m s am 1 5.
This equivalent reistance is also not a fixed value but varies with load current.
Find these numbers on the panel spec sheet.
Nominal rated maximum kw p power out of a solar array of n modules each with maximum power of wp at stc is given by peak nominal power based on 1 kw m 2 radiation at stc.
This is the open circuit voltage the solar panel will produce at stc or standard test conditions stc conditions are the electrical characteristics of the solar panel at airmass of am1 5 irradiance of 1000w m 2 and cell temperature of 25 o c.
Max power voltage vmp.
I want go for diy procedure to curb cost.
The solar panel yield of a pv module of 250 wp with an area of 1 6 m2 is 15 6.
Please bail me out.
They have too high of a voltage to charge a 12v battery bank with a traditional charge controller but too low of a voltage to charge a 24v.
But i observed that on the solar panel specification label you may find current at the maximum power to be lower than the calculated one.
The voltage of the panel after it is turned on and operating normally under load current is flowing through the circuit.
The available solar radiation e ma varies depending on the time of the year and weather conditions.
Example of i v curve and ratings of a 12 v solar pv panel.
Be aware that this nominal ratio is given for standard test conditions stc.
For example if the solar panel is rated at 175 watts and the maximum power voltage vmp is given as 23 6 volts then calculate the current as 175 watts divided by 23 6 volts which is equal to 7.
On the inverter spec sheet look for the rated mpp voltage range.
R is the yield of the solar panel given by the ratio.
The solar panel has a v i curve which is shaped like this.
However based on the average annual radiation for a location and taking into account the efficiency η of the cell.
The i v curve for a typical 12 volt pv solar panel is shown at fig 2 above.
Mppt maximum power point controllers attempt to find the point at which the power v i is a maximum and so yield highest power from the panel.
This information can be found from the solar panel manufacturers data sheet please see example here.
Grid tie solar panels with 60 cells are often referred to as 20v nominal panels like the solarworld sunmodule 290w solar panel.
So you will have the maximum current when the panel is short circuited and the maximum voltage when the panel is open circuited.